Vacuum plant for thermal treatment “PV-900”

Appointment


Vacuum furnace “PV-900” is made for thermal treatment of body parts made of titanium alloys. This furnace can be used for dehydrogenization and annealing of welded constructions made of titanium alloys.

 

Advantages of the model


Plant “PV-900” produce heating a workpiece in a vacuum to a certain temperature, holding at this temperature and cooling in vacuum and in inert gas medium.
Structurally furnace “PV-900” is designed as cylindrical shape vacuum chamber. Chamber has a back cover from one side and front cover from another. The front cover is mounted on the truck and attached to the heating chamber through pneumatic connectors.
 


Назад

 

Specifications
Power supply voltage, V 380±10%
Rated frequency, Hz 50±1%
Number of phases 3
Installed power, kW 320
Operating temperature, °C 450 - 850
Maximum temperature °C 900
Operating dimensions, mm, not less:
 - length
 - width
 - height
3300
1440
1300
Charge weight, kg, not less 3000
Accuracy of temperature keeping in the operating zone, °C ±2
Number of operating zones, pcs. 6
Uneven temperature between the operating zones, °C ±3
Range of the heating rate, °C/ hour 60...200
Residual ultimate pressure, Pa (mm Hg) 6,65 x 10-3 (5 x 10-5)
Inleakage, l / x PA/sec (l µm Hg/sec) 4,7 (35)
Operating vacuum, PA (mm Hg) From 6,65 x 10-2
to 6,65 x 10-3
Time to reach vacuum, min:
 - from the atmospheric pressure to 6.6 x 10-1 Pa
 - from 6.6 x 10-1 PA to 6.6 x 10-3 PA

35
20
Allowable deflection of the base plate:
 - in the transverse direction, mm
 - in the longitudinal direction, mm
1,0
2,0
Furnace dimensions, mm, not more
 - length
 - width
 - height
14200
3980
4460